• Control system and accessories

    for our fan range
    from ZIEHL-ABEGG

Select your language

 
1051

Air conditioning control unit

Match code

PTE-6AHQX-L


Item number

ZR-303608

ApplicationPTE control systems / regulator
FeaturesIB=6,0 A
Functional principleIn systems with individual extraction, the outputs are used to control fans, dampers and heaters are controlled via the outputs. In central extract air systems, these devices are used in combination with control modules (CTE/AHX-L or AHX-L) are used. The devices control the extract air flap and heating for a compartment. a compartment, while at the same time the exhaust air volumes of all connected compartments. From the The speed is calculated from the sum of the is calculated and the connected fan is controlled. In addition control for a heat exchanger is also integrated.
Functional descriptionEquipment/characteristics:
• Main switch with bypass function
• Operation via rotary encoder, keys and LC multifunction display with clear text
• Sensor input 1 for section (in delivery: 1 x TFR model, item no. 00089846)
• Sensor input 2 for: Inlet air temperature, separate control circuit or 0-10 signal from humidity/temperature sensor (MFTG- 100V model, item no. 384033).
• Three 0 - 10 V outlets, alternatively 10 - 0 V e.g. for: flaps, heater, group 2, separate control circuit, PWM outlet, can alternatively be used as another 0 - 10 V outlet.
• Three relay outlets, e.g. for: fault, heater, flap, peak load, group switching.
• Networking of max. 32 devices via RS485 interface (Modbus) for inlet air temperature, alarm signals and central functions.
• Growth curves with start value, 2 inflexion points and an end value, for target value, minimum ventilation, maximum ventilation, heater 1, Heater 2.
• Automatic closing mechanism by adjusting the target value when the control range is exceeded.
• Function for regulating heat exchanger and inlet air flap.
• Integrated control for piglet nest warm water heater (heater 2)
• Special modes for washing and heating
• Integrated semiconductor fuse
• Alarm buffer for the last 10 reports, storage of min. and max.
• Temperature values
• Optional. Integration into remote maintenance system
Technical data1~230V, 50/60Hz, IP 54, 1,5 kg
Size (R = for pipe installation) / dimensions
Series
Motor size

Request this product

email Contact form

The fields marked with * are mandatory.
Privacy policy

We use system-related session cookies to ensure the function of this site and to simplify use. Furthermore, cookies are set by Google Analytics to help us optimise the content of the pages.
Accept everything
Only technically necessary cookies
Further information
arrow_upward